Sign In | Join Free | My burrillandco.com
Home > Explosion Proof Plug and Socket >

Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments

    Buy cheap Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments from wholesalers
     
    Buy cheap Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments from wholesalers
    • Buy cheap Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments from wholesalers
    • Buy cheap Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments from wholesalers
    • Buy cheap Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments from wholesalers

    Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments

    Ask Lasest Price
    Brand Name : Crown Extra
    Model Number : AC8060
    Certification : ATEX,CE,ROHS,CNEX,ISO9001
    Price : USD14-120 per pc
    Payment Terms : T/T, Western Union
    Supply Ability : 50000pcs/month
    Delivery Time : 5-7 working days
    • Product Details
    • Company Profile

    Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments

    Factory price 16A 32A 63A GRP material 220VAC anti corrosion and explosion proof 4Pins plug and socket

    Product Description:

    This Explosion Proof Plug and Socket carries the Ex D E IIC T6 Gb certification, ensuring compliance with stringent safety standards for hazardous environments containing explosive gases and dust. Its IP66-rated enclosure provides superior resistance to dust and water ingress, making it highly durable in extreme industrial conditions.

    Available in 16A, 32A, and 63A configurations, this connector offers versatile power solutions tailored to different operational demands. Additionally, its Class I, Division 1, Groups C & D explosion-proof classification confirms its suitability for high-risk settings—including chemical processing plants, oil refineries, and other industrial facilities where flammable substances may be present.

    Engineered for reliability, this robust plug and socket assembly delivers secure electrical connectivity while mitigating explosion hazards in challenging work environments.

    Features:

    • Product Name: Explosion Proof Plug and Socket
    • Ex Mark: Ex D E IIC T6 Gb
    • Material: GRP/Aluminum
    • Rated Current: 16A, 32A, 63A
    • Protection Level: IP66
    • Application: Hazardous Location
    • Features:
      • Blast-Proof Plug and Socket
      • Intrinsically Safe Plug and Socket
      • Hazardous Location Plug and Socket

    Technical Parameters:

    TypePlug & Receptacle
    Ex rateEx d e IIC T6 Gb
    Rated Current [A]163263
    Rated voltage220/380VAC
    Degree of protectionIP65
    Entries
    M25*1.5 (suitable for
    Φ8mm-Φ17mm cable)
    M40*1.5 (suitable for
    Φ13mm-Φ27mm cable)
    M40*1.5 (suitable for
    Φ13mm-Φ27mm cable)
    The cable for plugΦ8mm-Φ19mmΦ12mm-Φ28mmΦ12mm-Φ28mm

    Applications:

    Energy and Power Facilities
    Power Plants: Coal-fired Boiler Rooms, Gas Turbine Rooms
    Substations: Underground Distribution Rooms, Battery Rooms
    New Energy: Lithium Battery Production Workshops, Hydrogen Stations

    Special Industrial Environments
    Grain Processing: Flour Milling Workshops, Starch Drying Towers
    Pharmaceutical Companies: Alcohol Extraction Workshops, Solvent Recovery Areas
    Shipbuilding: Enclosed Cabins, Oil Tanker Pump Rooms

    Public Safety Areas
    Underground Pipeline Galleries: Gas Pipeline Layers, Integrated Pipeline Trench
    Transportation Hubs: Subway Transfers, Airport Fuel Depots
    Hospital Laboratories: Anesthetic Storage Rooms, P3 Laboratories



    Key Considerations When Selecting Explosion-Proof Products:

    1. Explosion-Proof Certification and Standard Compliance
    International Certification
    Must obtain mandatory certification for the region of use (e.g., China CNEx/PCEC, EU ATEX, China IECEx).
    Confirm that the explosion-proof markings are complete (e.g., Ex db IIB T4 Gb).
    Standard Compatibility
    Gas environments must comply with GB3836/IEC 60079 series. Dust environments must comply with GB12476/IEC 61241 Series

    II. Environmental Compatibility Selection
    Hazardous Area Classification
    Zone 0/Zone 1/Zone 2 (Gas)
    Zone 20/Zone 21/Zone 22 (Dust)
    Select the corresponding explosion-proof type based on the zone level (e.g., Zone 0 requires intrinsic safety type ia)
    Special Environmental Requirements
    Chemically corrosive environments: Select a 316 stainless steel housing
    Marine environments: Must pass a salt spray test (1000 hours or longer)
    High-temperature locations: Select an appropriate temperature level within groups T1-T6

    III. Technical Performance Parameters
    Core Protection Indicators
    Protection level ≥ IP65 (IP66 recommended for outdoor use)
    Shock resistance ≥ 7J (heavy industrial locations)
    Surface temperature ≤ 80% of the auto-ignition point of the material in the area
    Electrical Parameters
    Voltage fluctuation range (±20%)
    Protection type (Flameproof type d/Increased safety type e/Intrinsic safety type) i, etc.)
    Cable entry type (armored/anti-pullout)

    IV. Product Reliability Assessment
    Manufacturer Qualifications
    Possess an explosion-proof product production license
    Provide a complete type test report
    Record of successful application in the same industry for at least 3 years
    Quality Assurance
    Key components (such as transparent components) must pass pressure and weathering tests
    Provide MTBF (mean time between failure) data
    Warranty period ≥ 3 years (including explosion-proof structural integrity)

    V. Lifecycle Management
    Installation and Maintenance Requirements
    Must be installed by a qualified explosion-proof electrician
    Regularly inspect the gap between explosion-proof joints (≤ 0.15mm)
    Establish a dedicated maintenance file
    Eliminate the use of explosion-proof structures that have been officially eliminated by the state
    Mandatory testing is required upon reaching the design life (usually 8-10 years)
    Re-certification is required after a major incident

    Quality Explosive Atmospheres ATEX Explosion-proof Plug and Socket 16A 32A 63A for Hazardous Environments for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: crown extra lighting co. ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)